A study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

Su Hee Park, Sung Mo Choi, Kyung Soo Chung

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of mis comparison showed that the test and analysis results for specimens SAHl, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative man the AJJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

Original languageEnglish
Pages (from-to)491-510
Number of pages20
JournalSteel and Composite Structures
Volume8
Issue number6
DOIs
StatePublished - Dec 2008

Keywords

  • Concrete-filled steel square tube column
  • Constant central axial load
  • Fire resistance
  • Fire-resistance test
  • Numerical analysis
  • Without fire protection

Fingerprint

Dive into the research topics of 'A study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads'. Together they form a unique fingerprint.

Cite this