A study on the structural performance of new shape built-up square column under concentric axial load

Sun Hee Kim, Kyong Soo Yom, Sung Mo Choi

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Recently, in recognition of their outstanding structural performance, the use of Concrete Filled Steel Tube (CFT) columns has been increased. New shape welded built-up square tube was developed by the authors for broader usability using thin steel plates which were bent to be L-shaped (Channel) and each unit members were welded to form square steel tube as an cost-efficient use of expensive steel. In addition, since the rib placed at the center of the tube width acts as an anchor; higher load capacity of buckling is achievable. In order to apply the new shape built-up square columns, the structural behavior and stress distribution with parameter width of thickness (b/t), with and without rib were predicted. The New shape welded built-up square tube effectively delayed the local buckling of the steel tube, which led to a greater strength and ductility than regular HSS.

Original languageEnglish
Pages (from-to)1451-1464
Number of pages14
JournalSteel and Composite Structures
Volume18
Issue number6
DOIs
StatePublished - 1 Jun 2015

Keywords

  • Built-up square column
  • Composite effect
  • Concentric axial load
  • Width of thickness

Fingerprint

Dive into the research topics of 'A study on the structural performance of new shape built-up square column under concentric axial load'. Together they form a unique fingerprint.