TY - GEN
T1 - An Experimental Study on Air-Side Heat Transfer Coefficient of Fin-Tube Heat Exchanger for Refrigerator
AU - Kang, Byeonghyeon
AU - Jeong, Ungbeen
AU - Park, Myeonghyeon
AU - Lee, Dongchan
N1 - Publisher Copyright:
© 2026, Avestia Publishing. All rights reserved.
PY - 2026
Y1 - 2026
N2 - Improving the efficiency of refrigerator systems increasingly relies on performance-prediction simulations. Because refrigerator evaporators vary widely in size and configuration depending on the refrigerator type and capacity, a sufficient amount of experimental data is required to improve the accuracy of simulation-based performance predictions. In addition, although the overall performance of a refrigerator is influenced by the interactions among multiple components, such as the compressor, condenser, and expansion device, the evaporator can be regarded as one of the most critical components because it directly determines the cooling performance through heat exchange between the air side and the refrigerant side [1]. Accordingly, this study focuses on obtaining reliable experimental data to address the current lack of evaporator performance data. For a more detailed investigation of evaporator heat-transfer performance, the test section is divided into two regions: the air-side heat-transfer region and the refrigerant-side heat-transfer region. Heat transfer and pressure drop characteristics in each region are analyzed experimentally, and the resulting database is used to develop correlations for predicting heat-transfer coefficients. Ultimately, the objective of this study is to develop a heat exchanger model for a one-dimensional simulation framework. A total of six evaporator samples, denoted as Samples A-F, are used in the experiments. All samples are fin-tube heat exchanger evaporators, but they differ in geometric parameters such as the number of rows, fin pitch, and heat transfer area. These geometric differences lead to variations in the air-side and refrigerant-side heat-transfer coefficients and pressure drops. To determine the refrigerant-side heat-transfer coefficient, the air-side heat-transfer coefficient must first be identified, as can be understood from the thermal resistance network. Although a number of existing correlations are available for predicting the air-side heat-transfer coefficient, their applicability is often limited by the ranges of Reynolds number based on tube collar diameter (ReDc) and the number of tube rows. Therefore, this study aims to develop more generally applicable correlations for the air-side heat-transfer coefficient and pressure drop through extensive air-side experiments. The experimental apparatus is installed in a temperature-and humidity-controlled chamber, where the inlet air temperature and airflow rate on the air side of the evaporator are controlled according to a predetermined design of experiments. Based on the measured data, the air-side heat-transfer coefficient and pressure drop are expressed in terms of the dimensionless j-factor and f-factor, which were obtained in the ranges of 0.01-0.05 and 0.05-0.45, respectively. Using the functional form proposed by Wang [2,3] as a basis, new correlations for predicting the j-factor and f-factor were developed. In addition, refrigerant-side experiments will be conducted, and the resulting data will be used to develop predictive correlations for the refrigerant-side heat-transfer coefficient and pressure drop.
AB - Improving the efficiency of refrigerator systems increasingly relies on performance-prediction simulations. Because refrigerator evaporators vary widely in size and configuration depending on the refrigerator type and capacity, a sufficient amount of experimental data is required to improve the accuracy of simulation-based performance predictions. In addition, although the overall performance of a refrigerator is influenced by the interactions among multiple components, such as the compressor, condenser, and expansion device, the evaporator can be regarded as one of the most critical components because it directly determines the cooling performance through heat exchange between the air side and the refrigerant side [1]. Accordingly, this study focuses on obtaining reliable experimental data to address the current lack of evaporator performance data. For a more detailed investigation of evaporator heat-transfer performance, the test section is divided into two regions: the air-side heat-transfer region and the refrigerant-side heat-transfer region. Heat transfer and pressure drop characteristics in each region are analyzed experimentally, and the resulting database is used to develop correlations for predicting heat-transfer coefficients. Ultimately, the objective of this study is to develop a heat exchanger model for a one-dimensional simulation framework. A total of six evaporator samples, denoted as Samples A-F, are used in the experiments. All samples are fin-tube heat exchanger evaporators, but they differ in geometric parameters such as the number of rows, fin pitch, and heat transfer area. These geometric differences lead to variations in the air-side and refrigerant-side heat-transfer coefficients and pressure drops. To determine the refrigerant-side heat-transfer coefficient, the air-side heat-transfer coefficient must first be identified, as can be understood from the thermal resistance network. Although a number of existing correlations are available for predicting the air-side heat-transfer coefficient, their applicability is often limited by the ranges of Reynolds number based on tube collar diameter (ReDc) and the number of tube rows. Therefore, this study aims to develop more generally applicable correlations for the air-side heat-transfer coefficient and pressure drop through extensive air-side experiments. The experimental apparatus is installed in a temperature-and humidity-controlled chamber, where the inlet air temperature and airflow rate on the air side of the evaporator are controlled according to a predetermined design of experiments. Based on the measured data, the air-side heat-transfer coefficient and pressure drop are expressed in terms of the dimensionless j-factor and f-factor, which were obtained in the ranges of 0.01-0.05 and 0.05-0.45, respectively. Using the functional form proposed by Wang [2,3] as a basis, new correlations for predicting the j-factor and f-factor were developed. In addition, refrigerant-side experiments will be conducted, and the resulting data will be used to develop predictive correlations for the refrigerant-side heat-transfer coefficient and pressure drop.
UR - https://www.scopus.com/pages/publications/105044876435
U2 - 10.11159/ffhmt26.220
DO - 10.11159/ffhmt26.220
M3 - Conference contribution
AN - SCOPUS:105044876435
SN - 9781990800740
T3 - International Conference on Fluid Flow, Heat and Mass Transfer
BT - Proceedings of the 13th International Conference on Fluid Flow, Heat and Mass Transfer, FFHMT 2026
A2 - Kruczek, Boguslaw
A2 - Ahmed, Wael H.
A2 - Ein-Mozaffari, Farhad
A2 - Wang, Huasheng
A2 - Darkwa, Jo
PB - Avestia Publishing
T2 - 13th International Conference on Fluid Flow, Heat and Mass Transfer, FFHMT 2026
Y2 - 9 June 2026 through 11 June 2026
ER -