TY - JOUR
T1 - Effect of Surface Pretreatment and Plating Time on Electromagnetic Shielding Reliability of Electroless Plated Copper Layer Conductors
AU - Jung, Jae Pil
AU - Lee, Jung Hyun
AU - Sharma, Ashutosh
N1 - Publisher Copyright:
© 2022 The authors.
PY - 2022/3/22
Y1 - 2022/3/22
N2 - We have investigated the electromagnetic interference (EMI) shielding effect of copper conducting films prepared by electroless plating. The various EMI shielding films were made at different plating times (10, 20, 30, and 40 min). The influences of pretreatment and plating time on microstructure, thickness, adhesion (e.g., cross-cutting and pencil hardness), and electromagnetic shielding effectiveness were evaluated. The morphological features and thickness of EMI shielding films were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD) methods. The experimental results show that the best outcome of adhesion and electromagnetic shielding effectiveness was obtained at the pretreated film with 30 min of plating time. The pretreated film showed a cross-cutting 5B grade, 4H pencil hardness, and 75 dB shielding effectiveness. The results of electromagnetic shielding effectiveness of films indicate that a longer plating time (10-30 min) results in better electromagnetic shielding effectiveness. However, the adhesive strength becomes worse if the plating time is longer than 40 min.
AB - We have investigated the electromagnetic interference (EMI) shielding effect of copper conducting films prepared by electroless plating. The various EMI shielding films were made at different plating times (10, 20, 30, and 40 min). The influences of pretreatment and plating time on microstructure, thickness, adhesion (e.g., cross-cutting and pencil hardness), and electromagnetic shielding effectiveness were evaluated. The morphological features and thickness of EMI shielding films were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD) methods. The experimental results show that the best outcome of adhesion and electromagnetic shielding effectiveness was obtained at the pretreated film with 30 min of plating time. The pretreated film showed a cross-cutting 5B grade, 4H pencil hardness, and 75 dB shielding effectiveness. The results of electromagnetic shielding effectiveness of films indicate that a longer plating time (10-30 min) results in better electromagnetic shielding effectiveness. However, the adhesive strength becomes worse if the plating time is longer than 40 min.
KW - cross-cutting
KW - electroless plating
KW - electromagnetic interference
KW - pencil hardness
KW - shielding effectiveness
UR - http://www.scopus.com/inward/record.url?scp=85126349853&partnerID=8YFLogxK
U2 - 10.1021/acsaelm.1c01195
DO - 10.1021/acsaelm.1c01195
M3 - Article
AN - SCOPUS:85126349853
SN - 2637-6113
VL - 4
SP - 1019
EP - 1028
JO - ACS Applied Electronic Materials
JF - ACS Applied Electronic Materials
IS - 3
ER -