Abstract
This work aims at understanding and eliminating thermo-mechanically induced circumferential cracks that form during cooling for a 400 °C annealed copper (Cu) through-glass via (TGV) with a mean outer diameter of 47.5μm , made in Corning HPFS fused silica glass. An exponential dependence was found between Cu metallization thickness and the likelihood for the formation of circumferential cracks. For the conditions used in this study, no cracks were formed in the HPFS fused silica substrate for Cu metallization thicknesses <12μm , however, for thicknesses ≥12μm , circumferential crack formation exponentially increased. From finite element analysis (FEA) studies, the corresponding threshold stresses for the initiation of circumferential stresses at 12μm was predicted to be 140 MPa. Therefore, for 400 °C annealed Cu TGV with a mean outer diameter of 47.5μm , made in HPFS fused silica substrate, circumferential stresses can be eliminated when Cu metallization thickness of less than 12μm is used.
Original language | English |
---|---|
Article number | 9481891 |
Pages (from-to) | 354-360 |
Number of pages | 7 |
Journal | IEEE Transactions on Device and Materials Reliability |
Volume | 21 |
Issue number | 3 |
DOIs | |
State | Published - Sep 2021 |
Keywords
- annealing treatment
- Circumferential cracks
- copper
- cracks
- fused silica
- thermomechanical
- through-glass via (TGV)