T1 - Evaluation on the improvement of the fire alarm sounder by the sound insulation in apartment buildings
AU - Lee, Min Joo
AU - Lee, Ki Ryung
AU - Kim, Myung Jun
PY - 2010
Y1 - 2010
N2 - In apartments in Korea, fire alarm sounder systems consist of the fire bell that is installed at the stairway hall, and the emergency broadcasting device that is installed in the living room. Previous studies showed that fire alarm sounder systems installed in apartment buildings might not be able to adequately notify sleeping residents of a fire outbreak. Moreover, the rate of recognition of the fire bell's sound was very poor. This study considers the fire bell recognition conditions via sound attenuation in apartment buildings with a small floor area of 81 m 2 and a large floor area of 184 m 2. The A-weighted sound pressure level of various spots in the households and the differences between the sound pressure levels of the two points in front of and behind the door, D p, were measured. Results showed that the overall sound attenuation was significant, about 5 dBA, in the household with a large floor area. Also considered was the improvement in the fire alarm sounder hearing conditions using Raynoise (Ver. 1) and the D p of the bedroom doors.
AB - In apartments in Korea, fire alarm sounder systems consist of the fire bell that is installed at the stairway hall, and the emergency broadcasting device that is installed in the living room. Previous studies showed that fire alarm sounder systems installed in apartment buildings might not be able to adequately notify sleeping residents of a fire outbreak. Moreover, the rate of recognition of the fire bell's sound was very poor. This study considers the fire bell recognition conditions via sound attenuation in apartment buildings with a small floor area of 81 m 2 and a large floor area of 184 m 2. The A-weighted sound pressure level of various spots in the households and the differences between the sound pressure levels of the two points in front of and behind the door, D p, were measured. Results showed that the overall sound attenuation was significant, about 5 dBA, in the household with a large floor area. Also considered was the improvement in the fire alarm sounder hearing conditions using Raynoise (Ver. 1) and the D p of the bedroom doors.
KW - A-weighted sound pressure level
KW - Apartment
KW - D
KW - Fire alarm sounder system
UR - http://www.scopus.com/inward/record.url?scp=84868651195&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84868651195
SN - 9781617823961
T3 - 39th International Congress on Noise Control Engineering 2010, INTER-NOISE 2010
SP - 589
EP - 598
BT - 39th International Congress on Noise Control Engineering 2010, INTER-NOISE 2010
T2 - 39th International Congress on Noise Control Engineering 2010, INTER-NOISE 2010
Y2 - 13 June 2010 through 16 June 2010
ER -