Faraday's induction in nano-transformer

H. K. Kim, J. S. Hwang, S. H. Hong, S. W. Hwang, D. Ahn

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Faraday's induction experiment in a nanometer scale is presented. A nano-transformer with the coupling area of approximately 1 μm2 was fabricated, and the induced open circuit voltage as functions of the frequency and the magnitude of the input bias were measured. Our measured results show that the transformer behaves as a linear ideal transformer with the mutual inductance of 30 nH. This mutual inductance value is orders of magnitude larger than the one expected from 1 μm2 coupling area.

Original languageEnglish
Title of host publication2006 IEEE Nanotechnology Materials and Devices Conference, NMDC
Pages120-121
Number of pages2
DOIs
StatePublished - 2006
Event2006 IEEE Nanotechnology Materials and Devices Conference, NMDC - Gyeongju, Korea, Republic of
Duration: 22 Oct 200625 Oct 2006

Publication series

Name2006 IEEE Nanotechnology Materials and Devices Conference, NMDC
Volume1

Conference

Conference2006 IEEE Nanotechnology Materials and Devices Conference, NMDC
Country/TerritoryKorea, Republic of
CityGyeongju
Period22/10/0625/10/06

Keywords

  • Faraday
  • Induction
  • Nano
  • Transformer

Fingerprint

Dive into the research topics of 'Faraday's induction in nano-transformer'. Together they form a unique fingerprint.

Cite this