Abstract
In this study, three multi-span moment frames are fabricated and tested under reversed cyclic loadings. The test program includes a reinforced concrete (RC) specimen with typical monolithic connections, which fully satisfies the seismic specification of the special moment frame prescribed in ACI 318, and two hybrid post-tensioned precast concrete (HPPC) frame specimens, which are integrated using unbonded prestressing tendons throughout two-bay continuous spans. On this basis, excellent structural integrity and connection continuities in beam-column joints between discrete precast members can be achieved. The HPPC frame systems demonstrate seismic performances that are comparable to those of monolithic RC special moment frames designed based on the seismic design provision specified in ACI 318. In addition, key observations from the test program are presented comprehensively, where quantitative indexes are used to evaluate the seismic performance of the test specimens in terms of capacity, ductility, and damage characteristics, and the cyclic responses of the HPPC specimens were verified by using numerical analyses.
Original language | English |
---|---|
Pages (from-to) | 193-206 |
Number of pages | 14 |
Journal | ACI Structural Journal |
Volume | 119 |
Issue number | 5 |
DOIs | |
State | Published - Sep 2022 |
Keywords
- damage index
- post-tensioning
- precast concrete
- quasi-static cyclic load testing
- seismic performance
- two-bay frame