Spark damage studies of microgap gas chambers with various anode strip metals

H. S. Cho, W. S. Hong, N. Palaio, J. Kadyk, K. B. Luk, V. Perez-Mendez, K. S. Joo, J. Vujic

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Since the effects of spark damage by discharges and aging are very sensitive to metal used for anode strips, several microgap gas chambers (MGCs) have been fabricated with various anode strip metals: aluminum, gold, chromium, nickel, and titanium-tungsten, and a systematic study of spark damage effects has been made to compare their relative sensitivity to failure, over a range of electrical discharge energies. The results of aging studies are being presented separately.

Original languageEnglish
Pages (from-to)635-639
Number of pages5
JournalIEEE Transactions on Nuclear Science
Volume44
Issue number3 PART 1
DOIs
StatePublished - 1997

Fingerprint

Dive into the research topics of 'Spark damage studies of microgap gas chambers with various anode strip metals'. Together they form a unique fingerprint.