Structural characteristics of welded built-up square concrete filled tubular stub columns associated with concrete strength

S. H. Lee, S. H. Kim, J. S. Bang, Y. A. Won, S. M. Choi

Research output: Contribution to journalConference articlepeer-review

13 Scopus citations

Abstract

Thin Walled Cold-Formed Concrete Filled Tubular Square Column are manufactured by flare welding at center of column width for cold formed L shape plates of 4 piece and improved composite effect of concrete and steel by vertical inner anchor. Also, Axial resistance of concrete is increased by confine effect of steel tube and steel prevent local buckling of steel column. In this study, we introduced manufacture method of thin walled cold-formed square column steel square concrete filled tubular column and structural performance of the welded built-up square stub column was verified by structural test for ten specimens with parameters of concrete strength, type of steel tube, width to thickness ratio of steel tube.

Original languageEnglish
Pages (from-to)1140-1148
Number of pages9
JournalProcedia Engineering
Volume14
DOIs
StatePublished - 2011
Event12th East Asia-Pacific Conference on Structural Engineering and Construction, EASEC12 - Hong Kong, Hong Kong
Duration: 26 Jan 201128 Jan 2011

Keywords

  • Cold-formed
  • Inner Anchor
  • Stub column
  • Welded built-up square CFT column

Fingerprint

Dive into the research topics of 'Structural characteristics of welded built-up square concrete filled tubular stub columns associated with concrete strength'. Together they form a unique fingerprint.

Cite this